FIGURE 17
FLOW CHART TO PROGRAM THE DRIVE TO DISPLAY CUSTOM UNITS "012.0"
Notes: 1. The factory setting of Display Mode (Function No. 4.00) is Frequency ("0000"). 2. The factory setting of
Custom Units Significant Digits (Function No. 4.01) is "0100". 3. The factory setting of Custom Units Display
(Function No. 4.02) is Whole Numbers ("0000"). 4. The Custom Unit setting "012.0" will be displayed at full speed.
FIGURE 18
FLOW CHART SHOWING
MOTOR CURRENT, MOTOR VOLTAGE, AND BUS VOLTAGE ADDED TO THE BASIC DISPLAY *
*Function Nos. 4.04 – 4.06 set to "0001".