Kb-electronics KBRC-240D Manual de usuario Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
12
3
. Bidirectional Operation
Provides forward and reverse
operation using the Main Speed
P
otentiometer. Connect the
Main Speed Potentiometer high
s
ide to +15V terminal, wiper to
S
IG terminal and low side to
-15V terminal, as shown in
F
igure 9. Zero motor speed will
now be located at 50% rotation.
Rotating the Main Speed Potentiometer clockwise will increase motor speed in the
forward direction. Rotating the Main Speed Potentiometer counterclockwise will
increase motor speed in the reverse direction. Note: Jumper J5 must be set to the
“15V” position.
Note: If the motor runs in the opposite direction than is desired, disconnect power
and either reverse the high side and low side of the Main Speed Potentiometer wires
or reverse the motor leads to M1 and M2 terminals of Terminal Block TB1.
4. Bidirectional
Operation with
Reversing Contacts
Connect the Main
Speed Potentiometer
high side to the center
of the switch (type ON-
OFF-ON, SPDT switch
with center off position),
wiper to SIG terminal
and low side to COM
terminal. Connect the
“forward side of the
switch to the +15V ter-
minal and the “reverse”
side of the switch to the -15V terminal, as shown in Figure 10. Rotating the Main
Speed Potentiometer clockwise will increase motor speed in the direction selected by
the switch. Rotating the Main Speed Potentiometer counterclockwise will decrease
motor speed. Note: Jumper J5 must be set to the “15V” position.
G. Remote Start/Stop Switch Connection The control is sup-
plied with a prewired Start/Stop Switch, mounted on the front
cover. To operate the control from a remote Start/Stop Switch
(type (ON)-OFF-ON, SPDT), remove the white, black, and
red wires from START, RET and STOP terminals. The leads
may be taped and left in the control. The switch assembly
may be removed if a watertight seal is used to cover the hole
in the front cover. Connect the remote Start/Stop Switch
wires to START (momentary), RET (common) and STOP
(constant) terminals, as shown in Figure 11. After applying
power, momentarily set the Start/Stop Switch to the “START”
position. The motor will run at the set speed of the Main
Speed Potentiometer. To stop the motor, set the
Start/Stop Switch to the “STOP” position.
Note: To eliminate the Start/Stop function, connect
START and RET terminals with the jumper that is pro-
vided, as shown in Figure 12.
CAUTION! Eliminating the Start/Stop function
using a jumper will cause the motor to run at the
Main Speed Potentiometer setting when the AC line is applied.
+15V -15V SIGCOM
MAIN SPEED
P
OTENTIOMETER
(BACK VIEW)
WIPER (ORANGE)
LOW (WHITE)
H
IGH (VIOLET)
FIGURE 9 BIDIRECTIONAL MAIN SPEED
P
OTENTIOMETER CONNECTION
-15V SIGCOM +15V
R
EV
FWD
S
TOP
SWITCH
L
OW (WHITE)
HIGH (VIOLET)
WIPER (ORANGE)
(BACK VIEW)
MAIN SPEED
POTENTIOMETER
FORWARD-STOP-REVERSE
FIGURE 10 BIDIRECTIONAL MAIN SPEED
POTENTIOMETER CONNECTION WITH
REVERSING CONTACTS
WHITE
RED
BLACK
START
STOP
START/STOP SWITCH
STOPSTARTRET
FIGURE 11 – REMOTE
START/STOP SWITCH
CONNECTION
STOPSTARTRET
FIGURE 12 START/STOP
FUNCTION ELIMINATED
(JUMPER INSTALLED)
!
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 23 24