Kb-electronics KBVF-23P Manual de usuario Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 45
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
Electronic Inrush Current Limit (EICL™) Eliminates harmful inrush AC line current
during startup. Models KBVF-21D, 22D contain ICL in lieu of EICL™.
Short Circuit – Prevents drive failure if a short circuit occurs at the motor (phase-to-phase).
Motor Filter Reduces harmful voltage spikes to the motor.*
Regeneration – Eliminates nuisance tripping due to bus overvoltage caused by rapid decel-
eration of high inertial loads.
Undervoltage and Overvoltage – Shuts down the drive if the AC line input voltage goes
above or below the operating range.
MOV Input Transient Suppression.
Microcontroller Self Monitoring and Auto-Reboot.
*Only Models KBVF-21D, 22D, 13, 23, 23D, 14, 24, 24D, 26D Contain Motor Filter.
3.4 Trimpot Adjustments
Minimum Speed (MIN) – Sets the minimum speed of the motor. See Section. 13.1, on page 39.
Maximum Speed (MAX) – Sets the maximum speed of the motor. See Section. 13.2, on page 39.
Acceleration (ACC) Sets the amount of time for the motor to accelerate from zero speed
to full speed. See Section 13.3, on page 39.
Deceleration (DEC/B) Sets the amount of time for the motor to decelerate from full speed
to zero speed. See Section 13.4, on page 39.
Slip Compensation (COMP) – Maintains set motor speed under varying loads. See Section
13.5, on page 40.
Boost (DEC/B) In 50 Hz mode, the trimpot automatically becomes Adjustable Boost,
which can be used to set the Volts/Hz Curve for 50 Hz motors to obtain maximum perform-
ance. In 50 Hz Mode, the deceleration time is automatically set to the same as the accelera-
tion time. See Section 13.6, on page 41.
12
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 44 45

Comentarios a estos manuales

Sin comentarios