INSTALLATION AND OPERATING INSTRUCTIONS
KBWS WHISPER DRIVE
PULSE WIDTH MODULATED (PWM)
!
See Safety Warning on Page 5 before
installing and operating this control
The information contained
in this manual is intended to be accurate.
However, the manufacturer retains
the right to make changes in design
which may not be included herein.
DC Motor Speed Control with Built-In
Input Signal Isolation
See Table 1 on page 10 for a list of KBWS
Models covered by this manual
TM
A COMPLETE LINE OF MOTOR DRIVES
© 2001 KB Electronics, Inc.
Hi-Pot
Te st ed 
1500 VAC
Note: A Plug-In Horsepower Resistor®
must be installed for this product to
operate (supplied separately).
Vista de pagina 0
1 2 3 4 5 6 ... 24 25

Indice de contenidos

Pagina 1 - KBWS WHISPER DRIVE

INSTALLATION AND OPERATING INSTRUCTIONSKBWS WHISPER DRIVEPULSE WIDTH MODULATED (PWM) !See Safety Warning on Page 5 beforeinstalling and operating this

Pagina 2

102.1955.5KBWS-12, 15, 22D:KBWS-25D:8 PLACESØ0.19Ø4.833.1780.51.2531.80.9524.13.8096.5FIGURE 2B – MECHANICAL SPECIFICATIONS (Inches / mm)TABLE 1 – EL

Pagina 3

11II. PLUG-IN HORSEPOWER RESISTOR®A Plug-In Horsepower Resistor® (PHR) must beinstalled for the KBWS to operate. Select a Plug-In Horsepower Resist

Pagina 4

12Note: Disconnect main power when installing or changing the Plug-InHorsepower Resistor®.III. WIRING INSTRUCTIONSWarning! Read Safety Warning, on pa

Pagina 5

Warning! Do not wire switches or relays inseries with the armature. Armature switchingcan cause catastrophic failure of motor and/or control.

Pagina 6 - 2 HP. They

analog signal voltage to P2 (signal) and P1 (-) ter-minals. Adjustment of the MIN trimpot may benecessary to achieve a 0 Volt DC output with a0 Volt

Pagina 7

Potentiometer setting. When the Enable Switch is opened, the control will coastto the minimum speed setting.Warning! Do not use Enable as a safety di

Pagina 8 - FIGURE 1 – CONTROL LAYOUT

VI. RECOMMENDED HIGH VOLTAGE DIELECTRIC WITHSTAND TESTING (Hi-Pot Testing)Note: This control has been Hi-Pot tested at 1500 Volts AC.Testing agencies

Pagina 9

172130AC KILOVOLTSRETURNH. V.(MAIN POWER DISCONNECTED)TERMINALS TOGETHERCONNECT ALL SPEED CONTROLHIGH VOLTAGE DIELECTRIC WITHSTAND TESTERMOTOR SPEED C

Pagina 10 - TABLE 1 – ELECTRICAL RATING

VII. OPERATION. (You must read the Safety Warning on page 5 before proceeding).After the KBWS has been properly setup, the startup procedure can begin

Pagina 11 - HORSEPOWER RESISTOR®

Warning! If possible, do not adjust trimpots with main powerapplied. If adjustments are made with main power applied, an insu-lated adjust

Pagina 12 - 2 0.1 9838 7.5

TABLE OF CONTENTSSection Pagei. Simplified Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4ii. Sa

Pagina 13 - POTENTIOMETER CONNECTION

To Calibrate the MIN Trimpot:1. Adjust the MIN trimpot to the desired positionand set the Main Speed Potentiometer fullycounterclockwise.2. Moni

Pagina 14 - CONNECTION

CAUTION! Adjusting the CL above 150% of motor rating can cause overheat-ing and demagnetization of some PM motors. Consult the motor manufacturer.Do

Pagina 15 - VOLTAGE SELECTION

Note: If the IR compensation is set too high, unstable (oscillatory) operation willresult.To Calibrate the IR Trimpot:1. Run the motor at approximate

Pagina 16

Note: In some applications, especially those requiring the motor tocycle on and off or from one speed to another or from stop to highsp

Pagina 17 - AC KILOVOLTS

XII. LIMITED WARRANTYFor a period of 18 months from the date of original purchase, KB Electronics, Inc.will repair or replace, without charge, device

Pagina 18

RECONDITIONING THE BUS CAPACITORS If this drive has been in storage for over one year it is necessary to recondition the power supply bus capacitors.

Pagina 19 - FIGURE 12 – MIN

Figures Pages1. Control Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82A. Mechanica

Pagina 20 - FIGURE 13 – ACC

i. SIMPLIFIED OPERATING INSTRUCTIONSIMPORTANT – You must read these simplified operating instructions before proceed-ing. These instructions are to b

Pagina 21 - FIGURE 16 – IR TRIMPOT RANGE

5ii. SAFETY WARNING! Please read carefullyThis product should be installed and serviced by a qualified technician, electrician,or electric

Pagina 22

I. INTRODUCTIONThank you for purchasing the KBWS. KB Electronics, Inc. is committed to providingtotal customer satisfaction by producing quality prod

Pagina 23

The KBWS contains built-in isolation for all signal inputs. This includes input signalvoltage, Main Speed Potentiometer terminals, Inhibit Circuit an

Pagina 24 - XII. LIMITED WARRANTY

8Plug-InHorsepowerResistor®(Supplied Separately)KBWS180V 90VA+A-L1L2CLPWR ONJ1P3 P2 P1CON1IRCLDECMIN ACCMAXFIGURE 1 – CONTROL LAYOUT(Illustrates Fa

Pagina 25

9KBWS180V 90VA+A-L1L2CLPWR ONJ1P3 P2 P1CON1IRCLDECMIN ACCMAX2.9875.81.2331.40.4812.34.301093.6292.13.8096.5FIGURE 2A – MECHANICAL SPECIFICATIONS (Inch